top of page
LineWatch Logo Inverse.png

LineWatch LLT

Check Tool.pngs-Shadow.png

The Live Line Tester (LLT) is the most accurate hot stick power meter for the distribution grid, designed for measuring phase-to-neutral voltage, current, power flow, and phase angle on live lines up to 34.5 kV. It provides high precision with 0.1% accuracy for voltage and 0.5% for current, simplifying the calibration of LineWatch M sensors in the field. The LLT combines voltage, current, power, and phase angle measurements in one portable device and supports real-time monitoring via wireless communication, enhancing efficiency in live line testing.

LineWatch LLT

LLT - Shadow.png

Features & Benefits:

  • High-Precision Measurement: The most accurate hot stick power meter available, offering 0.1% class precision for voltage measurements, 0.5% for current, and 0.6% for power factor. Trustworthy data ensures reliable, on-site decision-making.

  • Wireless Connectivity: Effortlessly connect tablets or laptops via the 2.4GHz ISM Band for real-time monitoring. This wireless interface provides unmatched flexibility in the field, making Line measurement and calibration smooth and efficient.

  • Multi-Functional Capabilities: Delivers real-time, precise measurements of current, voltage, phase angle, and both real and reactive power. This comprehensive data enhances visibility into high-voltage system performance, supporting efficient live line testing and informed decision-making.

  • Automated Calibration Tool: The LLT offers automated calibration for medium voltage sensors in the field, enhancing efficiency and minimizing manual calibration needs.

Applications:

  • Capacitor Bank Management: Measure voltage, current, and power factor at capacitor banks to ensure optimal reactive power compensation.

  • Transformer Testing and Monitoring: Use LLT to check the real-time power flow, phase angle, and current at MV transformers during maintenance.

  • Grid Performance Verification: Perform spot checks on phase-to-neutral voltage and current on MV lines to confirm the integrity of the distribution grid.

  • Switchgear Maintenance: Use LLT during maintenance of MV switchgear to ensure that all components function properly under live conditions.

  • Load Analysis: Conduct load measurements at critical points in the MV network to analyze power flow and assess equipment loading.

Software Tools:

  • On-Site Monitoring Interface: Provides real-time monitoring of key electrical parameters, such as voltage, current, power factor, and phase angle, ensuring precise data collection for diagnostics.

  • Automated Calibration Application: Designed for efficient MV sensors calibration in the field, reducing manual effort and ensuring accuracy in calibration processes.

Screenshot 2024-10-16 130115.png
Screenshot 2024-10-16 130217.png

TABLE OF CHARACTERISTICS

Screenshot 2024-10-23 094115.png
Call Center Headset

CONTACT US

What can we do for you today?

Whether you need information about our solutions, a project requiring specialist support or any other requests, do not hesitate to contact us. We will get back to you very soon.

Thanks for submitting!

Sample Request

Thanks for submitting!

bottom of page